With over-voltage and under-voltage protection functions.
With dual input threshold: it is required that the power factor is lower than the input threshold setting value and the reactive power is greater than the minimum set of capacitors before it is input, effectively preventing switching oscillations.
The input and removal delays can be adjusted separately, which is more applicable to the power grid.
Capacitor capacity input function, automatic identification number method for optimized switching.
There is a settable re-investment lock time to ensure that the capacitor has enough discharge time before being turned on
JKW-3DC Three phase common compensation intelligent reactive power compensation controller with dynamic output
Main purpose and scope of application
JKW-3 series intelligent low-voltage reactive power compensation controller (controller for short) is a special equipment for low-voltage power distribution system to compensate reactive power. It is based on the industry standard of the People’s Republic of China JB/T9663 and the power industry standard DL/ T597 design. The sampled physical quantity is reactive power, and the DC level output can directly drive intelligent composite switches and capacitive non-contact switches to switch power capacitors. It has the advantages of beautiful appearance, novel design, multiple functions, good control performance, and high reliability. It is in a leading position among similar domestic products and provides a brand-new equipment for power distribution automation. The words displayed when this series of products are powered on indicate the program version of the product.
This product complies with: industry standard JB/T9663-2013 (our company is the main drafting unit of this standard).
Model and meaning
Working conditions
1. Power supply voltage: the rated value is AC 380V/220V, and the fluctuation cannot exceed ±20%;
2. Ambient temperature: -25°C~55°C;
3. Relative humidity: the maximum relative humidity is 90% (at 20°C) ;
4, altitude: not more than 2000m;
. 5, environmental conditions: no explosion hazard medium flammable, non-corrosive metal gas and damage of an electrically insulating conductive dust;
Main technical parameters
1. Rated current: AC 0~5A;
2. Rated voltage: AC 220V/380V;
3. Contact capacity: dynamic DC12V/50mA per
branch; 4. Current input impedance: ≤0.02Ω;
5. Shell Protection level: IP30;
6. Frequency: 50Hz;
7. Sensitivity: 30mA;
8. Insulation voltage: 690V;
Features
1. Real-time display of network conditions: including reactive power, power factor, secondary current, primary current, system voltage, etc. (by clicking the up and down keys to switch during automatic operation).
2. Automatically identify the polarity of the sampling signal, and there is no concern about the polarity of the wiring.
3. It has the function of power-off memory for setting parameters, and the data will not be lost after power-off.
4. With over-voltage and under-voltage protection functions.
5. With dual input threshold: it is required that the power factor is lower than the input threshold setting value and the reactive power is greater than the minimum set of capacitors before it can be used to effectively prevent switching oscillations.
6. The input and removal delays are separately adjustable, which is more applicable to the power grid.
7. Capacitor capacity input function, automatic identification numbering method for optimized switching.
8. There is a settable re-investment lock time to ensure that the capacitor has enough discharge time before being turned on.
9. The output signal can be set to close a certain group or open a certain group of work.
10. Various parameters are all digitally adjustable, which can be widely applied to different power grid conditions.
11. Strong anti-interference ability, can directly resist interference pulses from peripheral common mode amplitude 2000V.
Factory setting values of various parameters
Code | meaning | Setting value | Adjustable range |
P-00 | Current polarity recognition method | AUTO | AUTO automatic/HAND manual |
P-01 | Power factor input threshold | 0.95 | 0.800~1.000 |
P-02 | Power factor cut off threshold | 1 | 0.900~-.900 |
P-03 | Input delay | 5 | 0.1~100s |
P-04 | Cut-off delay | 5 | 0.1~100s |
P-05 | Overvoltage protection | 440/245 | 400~500 / 230~270 |
P-06 | Recast lock time | 30 | 0~240s |
P-07 | Transformer ratio | 500 | 5~9000 |
C-01~C-12 | Capacitor capacity | 5 | 0~200kvar |
Main specifications and models
Product number | Hole Size | Sampling voltage | Signal frequency | Number of control groups | monitor | Total Weight | Replace the old model |
JKW-3SC-12D | 113×113 | Line voltage 380V | 50/60Hz | 1~12 | Luminous Digital | 0.9kg | JKWD15 |
JKW-3DC-12D | 113×113 | Phase voltage 220V | 50/60Hz | 1~12 | Luminous Digital | 0.9kg | JKWD2C |
JKW-3SA-16D | 139×139 | Line voltage 380V | 50/60Hz | 1~16 | Luminous Digital | 0.95kg | - |
JKW-3SA-19D | 139×139 | Line voltage 380V | 50/60Hz | 1~19 | Luminous Digital | 0.95kg | - |
Wiring schematic diagram
If you have any enquiry about quotation or cooperation,please free to email us ata65148373@163.comor use the following enquiry form,Our sales representative will contact you within 24 hous.thank you for your interest in our products.
Share our Product over the Social Networks
Search across our website