狠狠色噜噜狠狠狠狠7777米奇,狠狠色噜噜狠狠狠狠色综合久AV,狠狠色欧美亚洲狠狠色WWW,狠狠色婷婷久久一区二区三区

Shanghai Zhiyue Electric Co., Ltd    021-53080810   a65148373@163.com
China Zhiyue

Capacitor switching switch

CJ19-25 32 43 Switching capacitor contactor
  • CJ19-25 32 43 Switching capacitor contactor

CJ19-25 32 43 Switching capacitor contactor

1. The contactor is equipped with a current-limiting resistor, which can suppress the closing inrush current within the allowable range;
2. The contactor is a direct-acting double-breakpoint structure, with flexible action mechanism, convenient manual inspection and compact structure;
3. Contactor terminal It is covered by an insulating cover, which is safe and reliable;
4. The contactor can be fastened with screws, or it can be buckled on a 35mm or 75mm standard mounting rail;

Detailed introduction

CJ19-25 32 43 Switching capacitor contactor

CJ19-25 32 43 Switching capacitor contactor

Main purpose and scope of application

CJ19 series switching capacitor contactor is suitable for AC 50Hz, rated working voltage to 380V/660V power system, for low-voltage reactive power compensation equipment to put or cut capacitors to improve power factor. The contactor is equipped with an inrush current suppression device, which can effectively reduce the impact of the closing inrush current on the capacitor, and can replace the original switching device consisting of three XD1 current-limiting reactors and a CJ10 contactor.
This product complies with: national standards GB14048.1, GB14048.4, GB14048.5, IEC60947-4-1.

Model and meaning

Contactor model Auxiliary contact combination Number of contacts Contact mark
Normally open (moving and closing) Normally closed (moving off) Normally open (moving and closing) Normally closed (moving off)
CJ19-25 CJ19-32 CJ19-43 20E 2 - 13, 14, 23, 24 -
02E - 2 - 11, 12, 21, 22
11E 1 1 13, 14 21, 22
CJ19-63 CJ19-95 21E 2 1 13, 14, 33, 34 21, 22
12E 1 2 13, 14 21, 22, 31, 32
CJ19-115 CJ19-150 CJ19-170 10E 1 - 13, 14 -
01E - 1 - 11, 12

Working principle
When the control circuit is energized, the contactor is closed, and the upper main contact connected in the current-limiting resistance line is connected before the lower main contact, so as to suppress the inrush current. After the completion, it will be disconnected and reset instantly, during which the lower main contact The head enters normal work, and when the circuit is disconnected, it is completed by the lower main contact. Each performs its duties. Because the current-limiting resistor is connected instantaneously, it will not cause long-term power waste and burnout of the resistor.

Working conditions
1. The altitude of the installation site should not exceed 2000m;
2. The upper limit of the ambient air temperature should not exceed +40℃, and the lower limit should not be lower than -5℃;
3. The relative humidity of the installation site should be +40 at the highest temperature The temperature does not exceed 50%, and the relative humidity can be higher at a lower temperature. The monthly average minimum temperature of the wettest month does not exceed +20℃, and the average maximum relative humidity of the month does not exceed 90%, due to temperature changes. Measures must be taken for the condensation on the product;
4. Installation conditions: The installation incline to the vertical surface does not exceed ±5 °;
5. Pollution degree: Level 3;
6. Shock and vibration: In the absence of significant shaking, shock and vibration The place;

Structural features
1. The contactor is equipped with a current-limiting resistor, which can suppress the closing inrush current within the allowable range;
2. The contactor is a direct-acting double-breakpoint structure, with flexible action mechanism, convenient manual inspection and compact structure;
3. Contactor The terminal is covered by an insulating cover, which is safe and reliable;
4. The contactor can be fastened with screws, or it can be buckled on a 35mm or 75mm standard mounting rail; 

Main technical parameters

model CJ19-25 CJ19-32 CJ19-43 CJ19-63 CJ19-95 CJ19-115 CJ19-150 CJ19-170
Conventional heating current Ith A 25 32 43 63 95 250 250 250
Rated working current Ie AC-6b A 17 25 29 43 74 87 115 130
Controllable capacitor
kvar
230V-250V 6 9 10 15 29 35 45 52
400V-450V 12 15 20 30 50 60 80 90
690V 10 15 20 30 45 55 65 75
Equipped with fuse model RT16-25 RT16-32 RT16-50 RT16-63 RT16-125 RT16-160 RT16-160 RT16-250
Inrush current suppression capability (current limit multiple) times 20In
Line
Circle
Working voltage V 220, 380 or according to user requirements
Range of motion 0.85~1.1Us
Power consumption
VA
start 90 230 300
Hold 8 20 twenty two
Electrical life 104 times 10 8 6 2
Mechanical life 104 times 100 80 60 20
Maximum operating frequency times/h 300 120
Rated insulation voltage V 500 660 1000
Auxiliary contact Conventional heating current A 10
Electric life AC-15 360VA 12
104 times DC-13 33W 12
The smallest load that can be connected 6V×10mA
Current limiting resistor input time ms 7~9

Shape and installation dimensions

CJ19 switching capacitor contactor Amax Bmax Cmax
CJ19-25 45 160 124
CJ19-32 57 157 132
CJ19-43 57 157 136
CJ19-63 76 175 150
CJ19-95 85 195 160
CJ19-115 121 220 156
CJ19-150 121 220 156
CJ19-170 121 220 156

Ordering instructions
1. When ordering, it must be pointed out:
a. The complete name and model of the contactor;
b. The rated control power supply voltage and frequency of the coil;
c. The order quantity;
d. The auxiliary contact composition code.
2. Order example: CJ19-43/11E, 220V/50Hz; it means that the current of the switching capacitor contactor is 43A, the coil voltage is 220V 50Hz, and the auxiliary contact has one normally open and one normally closed.

Message Feedback

If you have any enquiry about quotation or cooperation,please free to email us ata65148373@163.comor use the following enquiry form,Our sales representative will contact you within 24 hous.thank you for your interest in our products.

Get to know Us Better Now!

Share our Product over the Social Networks

Search!

Search across our website